RJ LAB CRAFT INDIA PVT. LTD. is a trusted manufacturer and supplier of high-performance Auto Bypass Fume Hoods designed to provide superior operator protection, consistent airflow performance, and efficient containment of hazardous fumes, vapors, and airborne contaminants. Engineered for advanced laboratory safety, our Auto Bypass Fume Hoods help maintain stable face velocity even when the sash position changes, improving both safety and operational efficiency.
Designed for modern laboratories handling critical chemical processes, our Auto Bypass Fume Hoods offer intelligent airflow management, durable construction, and reliable long-term performance.
An Auto Bypass Fume Hoods is a ventilated laboratory enclosure equipped with an automatic bypass system that adjusts airflow as the sash opens or closes. This design helps maintain more consistent face velocity, reduces excessive turbulence, and improves containment performance compared to conventional fume hoods.
When the sash is lowered, the bypass opening allows additional airflow through the hood to help maintain safe operating conditions. This makes Auto Bypass Fume Hoods suitable for laboratories where stable airflow control and enhanced user protection are important.
At RJ LAB CRAFT INDIA PVT. LTD., our Auto Bypass Fume Hoods are designed for performance, safety, and durability.
Automatic bypass airflow design
Consistent face velocity performance
Improved containment efficiency
Reduced turbulence during sash movement
Enhanced operator protection
Durable sash mechanism
Chemical-resistant interior construction
Efficient exhaust performance
Utility provisions for gas, water, and electrical points
Custom-built sizes and configurations available
We manufacture Auto Bypass Fume Hoods in different material options based on laboratory and process requirements :
CRCA Powder Coated Construction
GI Construction
Stainless Steel (SS 304 / SS 316)
Polypropylene (PP) for corrosive environments
Phenolic Resin Work Surfaces
Chemical-Resistant Liners and Baffles
Our Auto Bypass Fume Hoods are widely used in :
Pharmaceutical Laboratories
Chemical Research Laboratories
Analytical Testing Laboratories
Petrochemical Laboratories
Educational and Institutional Labs
Government Research Facilities
Environmental Testing Laboratories
Hospitals and Diagnostic Laboratories
Process Development Laboratories
Specialty Chemical Laboratories
Auto bypass systems provide several performance and safety advantages, including :
Better airflow stability
Improved user safety
Enhanced containment control
Reduced risk of exposure to hazardous fumes
Energy-efficient airflow management
Support for safer laboratory operations
Reliable performance during varying sash positions
This design is especially useful in laboratories where maintaining controlled airflow is critical.
Every laboratory has unique requirements. We provide customised Auto Bypass Fume Hood solutions based on :
Laboratory layout
Airflow and ventilation requirements
Chemical compatibility
Ducted exhaust system needs
Utility integration requirements
Process-specific design parameters
Our engineering team develops practical solutions tailored to your application and safety requirements.
| Parameter | Specification |
|---|---|
| Product Type | Auto Bypass Fume Hood |
| Application | Chemical handling, research, testing, analysis and laboratory processes involving hazardous fumes, vapours and gases |
| Construction | Heavy-duty modular construction suitable for laboratory applications |
| External Body | GI powder-coated steel or SS 304/316, PP as required |
| Internal Lining | PP / FRP / Phenolic Resin / Epoxy-coated sheet / SS, selected according to application |
| Standard Widths | 1200 mm, 1500 mm, 1800 mm and 2400 mm; customized sizes available |
| Overall Dimensions | Customized according to laboratory layout and application requirements |
| Worktop Height | Typically, 750–900 mm, depending on configuration |
| Sash Type | Vertical rising / horizontal sliding / combination sash |
| Sash Material | Toughened safety glass / laminated safety glass |
| Sash Mechanism | Counterbalanced mechanism for smooth and controlled operation |
| Bypass System | Automatic bypass air opening designed to maintain more consistent airflow as the sash is lowered |
| Bypass Airflow Control | Automatically regulated through the bypass opening according to sash position and exhaust system design |
| Work Surface | Epoxy Resin / Phenolic Resin / Ceramic / Granite / SS |
| Baffle System | Rear baffle system designed for controlled and uniform airflow distribution |
| Airfoil | Aerodynamic front airfoil to improve airflow entry and minimize turbulence |
| Exhaust System | Duct-connected exhaust system with suitably selected centrifugal exhaust blower |
| Airflow Configuration | Constant Air Volume (CAV) / application-specific exhaust configuration |
| Face Velocity | Application-specific; designed according to the required laboratory standard and verified during commissioning |
| Airflow Monitoring | Digital / electronic airflow monitor with visual and audible low-airflow alarm, optional |
| Lighting | Energy-efficient LED laboratory lighting |
| Electrical Supply | 230 V, 1 Phase, 50 Hz or as per project requirement |
| Utility Services | Water, gas, compressed air, vacuum and electrical sockets, as required |
| Sink | PP sink with suitable waste connection, optional |
| Service Fixtures | Laboratory-grade taps, valves and service outlets |
| Exhaust Duct Material | PP / FRP, selected according to chemical compatibility |
| Base Cabinet | Optional chemical-resistant storage cabinet / pedestal |
| Control Panel | Blower, lighting, airflow monitoring and alarm controls as required |
| Safety Features | Automatic bypass, airflow monitoring, low-airflow alarm, sash positioning/stopping provision and suitable safety features |
| Finish | Epoxy powder-coated / chemical-resistant finish |
| Chemical Resistance | Internal materials selected according to the chemicals, concentrations and process conditions |
| Customization | Dimensions, materials, lining, worktop, sash, bypass arrangement, utilities and accessories can be customized |
| Testing | Airflow, face velocity and containment performance can be tested according to project requirements |
| Design Standards | Designed with reference to applicable laboratory fume hood standards and project-specific requirements |
Experienced Auto Bypass Fume Hood manufacturer
Advanced airflow-focused design
Premium raw materials
Precision engineering and robust construction
Custom solutions for varied laboratory applications
Quality-tested products
Competitive pricing
Timely delivery support
Technical guidance and after-sales assistance
As a reliable Auto Bypass Fume Hood Manufacturer and Supplier in India, RJ LAB CRAFT INDIA PVT. LTD. provides solutions built for laboratory safety, efficient airflow management, and long service life. Our fume hoods are designed to support critical laboratory operations where performance consistency and operator protection are essential.
Whether you require a standard Auto Bypass Fume Hood or a customised solution for specialised applications, we deliver dependable systems that meet your laboratory requirements.
Contact RJ LAB CRAFT INDIA PVT. LTD. for customised Auto Bypass Fume Hood solutions tailored to your application.